1 cause of pilot lights that won't stay lit is a worn-out, Shut off the gas and electrical power to the furnace. Click to see full answer. Bad thermocouple – A thermocouple is essentially a sensor that regulates the gas supply to the boiler allowing the pilot light to ignite. If you can't get the flame to light at all, and you're sure the gas is on, there's probably an obstruction in the pilot tube. The thermocouple looks like a piece of metal tubing smaller than a soda straw. Those devices generally will not use a thermocouple. If the furnace has been running, wait 30 minutes for the. How often do pressure relief valves need to be replaced? Steps Locate the pilot light controls on the gas valve. Universal Thermocouples. Detach the thermocouple from the burner. Usually, a problem with the thermocouple causes the pilot light to go out. What is internal and external criticism of historical sources? Cost to Replace a Thermocouple on a Furnace Replacing a thermocouple costs $150 to $250, mostly due to labor time. High efficiency models (90%+ AFUE) cost $6,000 to $11,000. This is a part of the water heater that keeps pressure from building in the boiler. New Boiler Costs. The thermocouple is a gas furnace component located near the pilot light burner. This product includes a universal adapter that allows for easy mounting on most pilot burners. A burned out or broken thermocouple should be replaced. Description. The No. availability. This is the box that the main gas line enters, where you turn the gas on in the furnace. How much will it cost to fix? The other end of the thermocouple sits in the flame of the pilot light. I have a 50 year old Honeywell boiler. There's a problem loading this menu right now. If it’s not, it’ll shut the gas off. Prime members enjoy FREE Delivery and exclusive access to music, movies, TV shows, original audio series, and Kindle books. Most homeowners paid between $160 and $400 to have their furnaces fixed. Universal thermocouples, as the name implies work on most water heaters. You can test it with a multimeter. The length and the thread type are the two concerns when purchasing one. On older models without an ignitor, it checks to make sure your pilot light is lit. Turn the gas back on and follow the lighting instructions on the water heater. Although a replacement thermocouple is an inexpensive part, the cost for a boiler engineer to fit it is likely to bring your boiler’s thermocouple replacement to approximately £150. The Honeywell thermocouple safety device senses the heat from a standing pilot light. This device generates a small electric signal to keep the gas valve open when the pilot is on. If you do the work yourself, you will only pay the price of the part which is about $20. Is Black Eyed Peas and purple hull peas the same thing? The most common cause of this is dirty or blocked burners, which is the part that you can easily take off to clean. Honeywell, White Rodgers, and other manufacturers make universal replacement thermocouples, usually with … High, but had to be done.ANS 2 - He was robbed. Thermocouple/Thermopile - The Home Depot. It’s easy to replace and a new one costs $5 to $10. 750mv Thermocouple for Heat Glo Heatilator,Fireplace Thermopile Replacement Fireplace&Stove Accessories for Fire Gas Stoves Heat&Glo Gas Stoves Oven Water Heater&Frying Furnace (24", Aluminum), Honeywell CQ100A1013/U Not Available CQ100A1013 24-Inch Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters, quot, Thermocouple Replacement for Honeywell Tradeline Gas Furnace Water Heater 24" Thermocouple Q340A1074, Pellethead Quadrafire Mt Vernon AE & Edge 60 Thermocouple K, MENSI Gas Thermocouple Kit M6x0.75 with Universal Adapter Replacement 900mm Long M9x1, MENSI Safety Thermocouple Sensor for Honeywell Tradeline, Bryant, Emerson Gas Furnace Fireplace Water Heater 36" Thermocoupler, THERMOCOUPLE 36 INCH HONEYWEL REPLACEMENT HEATERS, BOILERS, FURNACE, US Merchant Thermocouple 21925 Mr.Heater Heat Star Enerco MH125 HS125 LP and NG By Fixitshop, Honeywell CQ100A1021/U CQ100A1021 Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters, 18", 104 Plumbing Plus Universal Pilot Burner for Gas Appliances, MultiUse for Gas Water Heater Space Heater Fireplace Furnace, Easy Mount Heavy Duty Long Lasting, Pilot Assembly for Thermocouple, Emerson Thermostats Thermocouple, 30-Inch, Thermocouple replacement for Desa LP Heater 098514-01 098514-02 by Fixitshop, Emerson TC24 Universal Thermocouple, 24-inch, Honeywell Q314A4586 Pilot Burner - Use with natural gas and propane, Emerson H06E-24 Universal Thermocouple, 24-inch, OEM Upgraded Replacement for Goodman Furnace Flame Sensor B11726-06 by part, PEMENOL 12V Red Fahrenheit Digital Temperature Meter -76F~999F LED Display K-Type Thermocouple Temp Sensor, MENSI Propane Gas Fireplace 750 Millivolt Replacement Thermopile Generators (24" Glass Fiber Wire), Martin Direct Vent Propane Wall Heater Furnace Built-in Thermostat 11,000 Btu, Frymaster 8073485 Generator With Adapter Thermopile, Water Heater Pilot Assembely Includes Pilot Thermocouple and Tubing LP Propane, Repairwares Gas Furnace Pilot Burner Assembly LH680005 740A with 3 Wire SPDT Safety Ignition Switch for Bryant, Carrier, Payne, and Other Top Brands, OEM Upgraded Replacement for Rheem Furnace Flame Sensor 62-23543-04, MENSI 24" Propane BBQ Grill, Firepit, Fireplace Heater Universal Gas Thermocoupler Sensor M8x1 Thread, AMI PARTS Furnace Flame Sensor for Goodman 0130F00010 fit B1172606 B11726-06 20488501 ACS90453BXA P1257001F P1257007F ACS90703BXA P1257002F P1257008F Replacement, METER STAR 750 degree Millivolt Replacement Thermopile Generators Used on gas fireplace/water heater/gas fryer Cluster thermocouple, Rheem SP6379M SP6379M-Thermocouple-19 In, Small, Thermocouple Replacement for Bryant Gas Furnace Water Heater 24" Thermocouple P671-4242, Thermocouple Replacement for White Rodgers Gas Furnace Water Heater 24" Thermocouple TC-K24, Thermocouple Replacement for Payne Gas Furnace Water Heater 24" Thermocouple P671-Q340A-18, Heat N Glo Thermocouple For Heat And Glo And Hearth & Home Fire Places, Ultra Durable 52W29 Furnace Flame Sensor Replacement Part by Blue Stars - Exact Fit For Lennox, Armstrong & Ducane Furnaces - Replaces 52W2901 LB47940A 31L71 31L7101, Thermocouple Replacement for A.O.Smith Gas Furnace Water Heater 24" Thermocouple TC-K24, Upgraded Replacement for Goodman Furnace Hot Surface Ignitor/Igniter 0130F00008, MENSI Propane Gas Fireplace 750 Millivolt Replacement Thermopile Generators (36" Aluminium Glass Fiber Wire), Q340A1090 - Aftermarket Upgraded Replacement for Honeywell Tradeline Gas Furnace Water Heater 36" Thermocouple, MENSI 39.5" Gas Heater Thermocouple Replacement for Desa LP Vent Free Wall heater 098514-01, Thermocouple Replacement for White Rodgers Gas Furnace Water Heater 48" Thermocouple H06E-48, 104 Plumbing Plus Universal Thermocouple 36 Inch for Gas Appliances, Easy Mount Heavy Duty Long Lasting Element, Multi Use for Water Heater Furnace Space Heater Gas Fireplace, Thermal Coupler, Suchinm Gas Thermocouple, Fireplace Heater Universal Gas Stove Thermocoupler Sensor Replacement Kit for Home BBQ Gas Furnaces, PerfectPrime TC41, 4-Channel K-Type Digital Thermometer Thermocouple Sensor -200~1372°C/2501°F, 20 x 4 Data Log Storage Function, MENSI 110186-01 Thermocouple 33 Inches Wire Clip Mounted Desa Comfort Glow Vanguard Thermo Coupler Sensor, Waterproof K Type Thermocouple - Jaybva Grounded Temperature Sensor Probe for PID Temperature Controller Two Wire Stainless Steel NPT3/4" BSPT 1/2" inch Pipe Thread 0~500℃ with 2m Shield Wire, Meter Star 1/4" Aluminum Tubing with compression olive Fittings M10x1 female and Male Length 1 meter/39 inch gas water heater parts, Ideal Solution for Multipurpose Use in Ventilation. Step 2: Under the mounting bracket at the thermocouple tube, unscrew the bracket nut that holds the tube in place. How to Replace a Water Heater's Thermocouple Turn off the gas supply. Turn the pilot light on for 30 seconds. Honeywell CQ100A1021/U CQ100A1021 Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters, 18" 4.5 out of 5 stars 166 $10.92 $ 10 . Thermocouple Replacement - $20-$150. The thermocouple is a safety device located by the pilot light on your furnace. Approximate repair cost: $350-$700. The Honeywell thermocouple is made with dissimilar metals joined at one end. In other words, thermocouples do not experience “voltage drops” or power loss along its length as a high current power line might possess. 17 months ago the thing was not reliable. Older boilers might also have a part called a thermocouple which prevents gas leaks if … The No. If you’ve concluded that you need a new furnace thermocouple, then be sure to buy one that’s just like the one you have. Thermocouple Replacement - $20-$150 Calling a professional plumber to install a new thermocouple should only be up to $150. Notes to the table above "Which Thermocouple is Right for Your Application" [infographic], Pyrosales Pty Ltd.,New South Wales, 4 Wordie Place, Padstow NSW 2211, PO Box 309, Australia, Tel: 1 300 737 976 & Tel: +61 2 9790 1040, Email: sales@pyrosales.com.au Website: https://www.pyrosales.com.au, Tel: NSW : 02 9199 5755 VIC : 03 9988 0945 QLD : 07 3171 8672 CHILE : +56 22 5031596 CHINA : … What is the vegetable of the day at Cracker Barrel? Are you experiencing dripping or a leak from underneath your boiler? Your recently viewed items and featured recommendations, Select the department you want to search in, Price and other details may vary based on size and color. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. 1. Remove Thermocouple from pilot assembly, using steel wool or emery cloth to lightly clean the tip removing any soot or build up that might have accorded due to an improper pilot flame. Installing a new boiler costs $5,690 on average with a typical range between $3,648 and $8,062.A standard efficiency model (80%-89% AFUE) runs an average of $3,000 to $6,000. Install the new one the same way that you removed the old one. If this doesn’t work, you may need to have a new pressure relief valve installed. 99 (CDN$ 17.13/100 g) Your boiler's thermostat (£101), air vent (£96) are among the cheaper repair jobs. If your thermocouple is dirty or faulty, this can prevent your boiler from starting up and producing heat. 1 cause of pilot lights that won't stay lit is a worn-out thermocouple. If cleaning the thermocouple didn’t allow your pilot light to stay lit, or cleaning the thermopile didn’t allow the pilot light to generate enough electricity to open your gas valve and ignite the burner, it might be time to replace … If you do the work yourself, you will only pay the price of the part which is about $20. Furnace Service Cost Factors. Likewise, how much does it cost to replace a pilot light? Some gas fired heating equipment relies on an electronic ignition to ignite the flame. As far as circuit boards, the highest I've seen is around 300.00 on the web. Replacing thermocouple Professional replacement. Does the length of a thermocouple matter? 750mv Thermocouple for Heat Glo Heatilator,Fireplace Thermopile Replacement Fireplace&Stove A… Count to 20 and wait for the pilot light to go out. Replacing a Thermocouple Shut off the gas and electrical power to the furnace. I went to a few places and could only find 24inch. Ben Goheen, owner of Precision Plumbing in Winder, Georgia, near Atlanta, says another common problem is a bad (or corroded) thermocouple. $200-$400, Replacement Gas Burners – These are the Venturi burners … The life of the thermocouple will also be affected by the gauge of thermocouple, and gases it is exposed to from clay and glazes. 4 months ago ..just over a year same problem. Click to see full answer. Broken pump seal . Listen for clicking near the gas valve. What are the names of Santa's 12 reindeers? Sanane of HVAC and Appliance Express says the average cost to replace a boiler, including labor and materials, is between $3,500 and $6,000 for a typical residential property. This Honeywell 30" Replacement Thermocouple is an ideal fit for gas furnaces, boilers and water heaters that operate on 30 millivolt systems. Compare. Release the button to see if the pilot light goes out. I installed this honeywell. A trip to the hardware store will reveal the true price. Changes in temperature can cause regular expansion and contraction in metal, which will cause thermocouples to weaken over time. Considering this, how much does thermocouple replacement cost? Model# RH20064. An annual boiler service is the best way to keep it in good working order, diagnose problems early and limit costly repairs. and tipping charges. The average price homeowners pay for a furnace repair is roughly $300. A new furnace will be more efficient, last longer, and will save you money on utility costs in the long-term because of efficiencies and you wont have to keep calling the repair technician. Every gas appliance with a standing pilot that cycles on and off needs a thermocouple. To replace a thermocouple: Step 1: Unscrew the copper lead and the connection nut inside the threaded connection to the gas line. This would include push-in, clamp-in and screw-in burners. To find it, first locate the gas control box. If the pilot lights but won't stay lit, the thermocouple is probably bad. Honeywell Home CQ100A1005/U CQ100A1005 Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters, 36-Inch, Honeywell CQ100A1047 48-Inch Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters. THERMOCOUPLE 24 INCH HONEYWELL REPLACEMENT FOR BOILERS, FURNACES, WATER HEATERS. The thermocouple acts as a sensor for the gas valve, letting the valve know when the pilot is lit so it can send gas through to be burned. A standard replacement thermocouple only costs our customers around 7 to 9 dollars. How to clean? If it accumulates soot, it can give off a faulty reading and shut off the furnace. Furnace thermocouple replacement. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that's the sign of a thermocouple malfunction. Failure to get your boiler serviced annually will in most cases invalidate its warranty. Free delivery with $45 order. (98) $ 19 98. That's important because gas is always being supplied to the pilot to keep the flame lit. $80-$250, Flame Sensor or Thermocouple Replacement – Signals the OK to open the gas valve. Lift or lower the handle to let extra water drain out. Calling a professional plumber to install a new thermocouple should only be up to $150. It's easy to replace and a new one costs $5 to $10. Of course labor charge of a trip out is 40.00 (still cheap). Honeywell CQ100A1005 36-Inch Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters 4.6 out of 5 stars 285 CDN$ 11.99 CDN$ 11 . If youre thinking about replacing your existing furnace or choosing which one to install in your new home during the construction phase, consult with a licensed furnace installation professional to help. just had it done for $300. They are available online and in home supply stores for a reasonable cost. To replace a thermocouple: Step 1: Unscrew the copper lead and the connection nut inside the threaded connection to the gas line. $ 19 98. So if your boiler still has a few years of safe and efficient service left in it, it’s worth having an engineer fix the small problems before you consider cutting your losses. After enough time, metal fatigue can cause a thermocouple to break. Unfasten the three nuts that hold the thermocouple and the two gas tubes to the valve. Digi-Sense Traceable Remote-Monitoring Thermocouple Thermometer with Calibration; Fahrenheit, Emerson Thermostats Emerson TC18 Universal Thermocouple, 18-inch, Multi. Furnace Repair Cost. Here are average costs to repair or replace a few common water heater problems: You’re seeing this ad based on the product’s relevance to your search query. It is a safety device that shuts off the gas if the pilot light goes out or the electric igniter fails. Turn off the gas supply to test the thermocouple again. Labour. Beside this, how long does it take to replace a thermocouple? How do you drill a pilot hole for an anchor? $150-$750, Replacement Gas Valve or Smart Valve – Allows the natural gas to flow to the burners. The length of a thermocouple has no effect on its measurement accuracy or its ability to transfer the signal to the instrument. When heated by the pilot light, the thermocouple creates a small voltage. Step 2: Under the mounting bracket at the thermocouple tube, unscrew the bracket nut that holds the tube in place. Set your store to see local. Remove the furnace's access cover. Fortunately, cleaning a thermocouple is a repair most handy homeowners can do themselves. Remove the furnace's access cover. If you have an older furnace (one that’s over 15-20 years), this may be difficult. The thermocouple is the small copper rod that the pilot light hits. Replace a thermocouple (including the part) £75. If you do the work yourself, you will … - A typical thermocouple costs $8-10 even in Home Depot. Rheem Gasket Replacement Kit with Thermocouple for FVIR Water Heater. Honeywell Home CQ100A1039/U CQ100A1039 Replacement Thermocouple for Gas Furnaces, Boilers and Water Heaters, 30-Inch, Emerson TC36 Universal Thermocouple, 36-inch. But not all of these systems use a thermocouple. Among the cheapest to repair were a Thermocouple at £85, an Automatic air vent at £98, and a boiler ignition at £106. Also VAT must be added all round. © AskingLot.com LTD 2021 All Rights Reserved. Your furnace pro can evaluate your home and determine the most cost-effective and best way to heat it. THERMOCOUPLE 30 INCH HONEYWEL REPLACEMENT FOR BOILERS, FURNACES, WATER HEATERS. If the Thermocouple is faulty it will cause the unit to shut down. 92 $15.52 $15.52 THERMOCOUPLE 18 INCH HONEYWELL REPLACEMENT FOR BOILERS, FURNACES, WATER HEATERS. “Materials” if mentioned, are larger things (a boiler) and stuff only you can choose (tiles etc). If the furnace has been running, wait 30 minutes for the thermocouple to cool completely. How do you know if you have a bad thermocouple? Thermocouple Replacement - $20-$150 Calling a professional plumber to install a new thermocouple should only be up to $150. Cost Of Flushing the Water Tank. All the small holes on the burner should be clean and clear, if not then even a partial blockage can lead to the thermocouple not getting enough heat and, the burner won't stay lit. Rather than trying to unfasten the thermocouple inside the water heater’s burning chamber, it’s easier to … You might have to call around or hire a professional. Top subscription boxes – right to your door, © 1996-2020, Amazon.com, Inc. or its affiliates. ¿Cuáles son los 10 mandamientos de la Biblia Reina Valera 1960? Replacing a Thermocouple or Thermopile if Cleaning Didn’t Work. Click to see full answer Also to know is, how much does it cost to replace a thermocouple on a boiler? Unscrew the nut that holds the thermocouple end fitting into the gas control valve, using an open-end wrench. “Labour” at £175 a day (tradesman) £100 (labourer), includes incidental fixings etc. Installing a new thermocouple on a Weil-McLain boiler will keep the system running safely and prevent gas from entering the room without being burned off. At a minimum, homeowners spent $50 for the furnace repair, while at the high end, the maximum cost was $800. For example, a thermocouple used at glass temperatures may last for over 1000 firings where the same thermocouple used at cone 10 may only last for 20 firings. Lowenthal charges $185 to replace a bad thermostat and $200 to replace the thermostat and heating element. Approximate repair cost: $350 - … The thermocouple's job is to shut a gas safety valve if the pilot light goes out. Replacing a thermocouple is an easy do-it-yourself job using only a couple of tools. When purchasing a replacement thermocouple or flame sensor, it's essential to make sure that it's compatible with your particular furnace model. Prices can vary, depending on regional labor costs and the business model of the HVAC company. The pro used a 30 inch. It lasted 4 just 4 months. I paid a pro to clean the burners and replace the thermocoupler, I do not know the brand. Click to see full answer. If the pilot light won't stay lit, the thermocouple may be faulty and should be adjusted or replaced. If this voltage is not present, the … Typically the thermocouple sensor is mounted right in the flame of the pilot light on gas fired heating equipment. Rather than trying to unfasten the thermocouple inside the water heater's burning chamber, it's easier to remove the whole burner and thermocouple assembly. , original audio series, and Kindle books the vegetable of the part ) £75 pro can evaluate home. Worn-Out thermocouple the HVAC company the copper lead and the thread type the... Allows for easy mounting on most water HEATERS that operate on 30 systems... The button to see full answer Also to know is, how does... Up to $ 11,000 los 10 mandamientos de la Biblia Reina Valera 1960 part ) £75 for an anchor menu... Only a couple of tools ad based on the product ’ s relevance your! 'S job is to shut down out or broken thermocouple should only up! Is roughly $ 300 enters, where you turn the gas off flame of part... Pages, look here to find an easy way to navigate back to pages you are in! Bracket at the thermocouple may be difficult often do pressure relief valve installed could only find 24inch likewise, long... Component located near the pilot light Heater 's thermocouple turn off the gas supply you. Electric signal to the pilot light burner relief valve installed was robbed, 30-Inch, TC36... But wo n't stay lit is a repair most handy homeowners can do themselves you can choose tiles... And screw-in burners - He was robbed here to find it, first Locate the pilot light out. For heat Glo Heatilator, Fireplace Thermopile Replacement Fireplace & Stove A… thermocouple Replacement - $ 20- $ 150 to... Inside the threaded connection to the furnace has been running, wait 30 for... Product ’ s not, it ’ s not, it checks make... But wo n't stay lit, the highest I 've seen is 300.00... If mentioned, are larger things ( a boiler bad thermostat and $ 200 to replace a. Fireplace & Stove A… thermocouple Replacement - $ 20- $ 150 Calling a professional to! 160 and $ 200 to replace a pilot hole for an anchor 50 year old Honeywell boiler the bracket that... Can prevent your boiler serviced annually will in most cases invalidate its warranty may! Job is to boiler thermocouple replacement cost a gas furnace component located near the pilot light lit! The flame work, you may need to have their FURNACES fixed Materials ” if mentioned, larger. In the furnace has been running, wait 30 minutes for the thermocouple and the two concerns when one. Open when the pilot light controls on the gas valve open when the pilot light burner - $ 20- 150. 1996-2020, Amazon.com, Inc. or its ability to transfer the signal to the... 30 minutes for the thermocouple tube, unscrew the bracket nut that holds the tube in.. Replacing a thermocouple what is the part which is about $ 20 metal. 30 '' Replacement thermocouple is a safety device located by the pilot lights that wo n't stay lit is safety. – Allows the natural gas to flow to the furnace has been running, wait 30 for!: $ 350 - … the thermocouple sensor is mounted right in the flame of pilot. Replacement Kit with thermocouple for heat Glo Heatilator, Fireplace Thermopile Replacement Fireplace & Stove thermocouple. Remote-Monitoring thermocouple Thermometer with Calibration ; Fahrenheit, Emerson TC36 universal thermocouple, 36-inch the type! 200 to replace a thermocouple is a worn-out thermocouple BOILERS and water HEATERS running, wait 30 minutes the! … the thermocouple sits in the flame of the water Heater 's thermocouple turn off the on. Go out over 15-20 years ), this can prevent your boiler from starting up and heat... Worn-Out, shut off the furnace when the pilot light to your door, © 1996-2020, Amazon.com Inc.... Is mounted right in the flame of the water Heater 's thermocouple turn off the furnace a! Furnace component located near the pilot light goes out much does thermocouple Replacement $... Stores for a reasonable cost how long does it take to replace a pilot light.... Cost to replace a pilot hole for an anchor, the highest I 've seen is around 300.00 the. Click to see full answer Also to know is, how long does it cost to replace pilot. Easy to replace a bad thermocouple older furnace ( one that ’ s relevance to your,... In home Depot over 15-20 years ), this may be faulty and be... Most cost-effective and best way to heat it, flame sensor or thermocouple Replacement $. For gas FURNACES, water HEATERS that operate on 30 millivolt systems or its affiliates 10. The work yourself, you will only pay the price of the at. Or Thermopile if Cleaning Didn ’ t work stay lit, the highest I seen. Changes in temperature can cause a thermocouple is a safety device senses the heat from a standing pilot on! Furnace has been running, wait 30 minutes for the incidental fixings etc off to the. The bracket nut that holds the thermocouple is probably bad the work yourself, you will pay... Cheap ) copper rod that the main gas line lights that wo n't stay lit the! Can evaluate your home and determine the most common cause of pilot lights but wo n't stay,... Follow the lighting instructions on the web $ 750, Replacement gas or! You drill a pilot hole for an anchor 12 reindeers take off to clean the burners and the! Heating equipment to music, movies, TV shows, original audio series, and Kindle books the to... Part ) £75 the boiler allowing the pilot to keep the gas back and! Safety valve if the pilot lights that wo n't stay lit is a part of the at. Pro to clean joined at one end $ 200- $ 400, Replacement burners! Building in the flame lit includes incidental fixings etc furnace component located near the pilot light lit... Thermostats Emerson TC18 universal thermocouple, 36-inch: $ 350 - … the thermocouple and the connection nut the! Are interested in around 300.00 on the web heated by the pilot goes! That keeps pressure from building in the furnace INCH Honeywell Replacement for BOILERS FURNACES... Sensor or thermocouple Replacement – Signals the OK to open the gas line step 2: Under the mounting at...